Follow
Chris Conant
Title
Cited by
Cited by
Year
Ultra-high-resolution ion mobility separations over extended path lengths and mobility ranges achieved using a multilevel structures for lossless ion manipulations module
AL Hollerbach, A Li, A Prabhakaran, G Nagy, CP Harrilal, CR Conant, ...
Analytical chemistry 92 (11), 7972-7979, 2020
552020
Melting proteins confined in nanodroplets with 10.6 μm light provides clues about early steps of denaturation
TJ El-Baba, DR Fuller, DW Woodall, SA Raab, CR Conant, JM Dilger, ...
Chemical Communications 54 (26), 3270-3273, 2018
412018
Assessing collision cross section calibration strategies for traveling wave-based ion mobility separations in structures for lossless ion manipulations
A Li, CR Conant, X Zheng, KJ Bloodsworth, DJ Orton, SVB Garimella, ...
Analytical chemistry 92 (22), 14976-14982, 2020
272020
Conformationally regulated peptide bond cleavage in bradykinin
DR Fuller, CR Conant, TJ El-Baba, CJ Brown, DW Woodall, DH Russell, ...
Journal of the American Chemical Society 140 (30), 9357-9360, 2018
262018
Rapid and simultaneous characterization of drug conjugation in heavy and light chains of a monoclonal antibody revealed by high-resolution ion mobility separations in SLIM
G Nagy, IK Attah, CR Conant, W Liu, SVB Garimella, HP Gunawardena, ...
Analytical chemistry 92 (7), 5004-5012, 2020
252020
Measurement and theory of gas-phase ion mobility shifts resulting from isotopomer mass distribution changes
CP Harrilal, VD Gandhi, G Nagy, X Chen, MG Buchanan, R Wojcik, ...
Analytical chemistry 93 (45), 14966-14975, 2021
182021
Ion mobility spectrometer and method of operating same
DE Clemmer, MA Ewing, SM Zucker, CRP Conant
US Patent 8,872,102, 2014
172014
Dynamic time-warping correction for shifts in ultrahigh resolving power ion mobility spectrometry and structures for lossless ion manipulations
AL Hollerbach, CR Conant, G Nagy, ME Monroe, K Gupta, M Donor, ...
Journal of the American Society for Mass Spectrometry 32 (4), 996-1007, 2021
162021
Selected overtone mobility spectrometry
MA Ewing, CRP Conant, SM Zucker, KJ Griffith, DE Clemmer
Analytical chemistry 87 (10), 5132-5138, 2015
162015
AutoCCS: automated collision cross-section calculation software for ion mobility spectrometry–mass spectrometry
JY Lee, A Bilbao, CR Conant, KJ Bloodsworth, DJ Orton, M Zhou, ...
Bioinformatics 37 (22), 4193-4201, 2021
152021
Substance P in solution: trans-to-cis configurational changes of penultimate prolines initiate non-enzymatic peptide bond cleavages
CR Conant, DR Fuller, TJ El-Baba, Z Zhang, DH Russell, DE Clemmer
Journal of The American Society for Mass Spectrometry 30 (6), 919-931, 2019
132019
Ion mobility spectrometry with high ion utilization efficiency using traveling wave-based structures for lossless ion manipulations
A Li, G Nagy, CR Conant, RV Norheim, JY Lee, C Giberson, ...
Analytical chemistry 92 (22), 14930-14938, 2020
122020
B.; Gunawardena, HP; Shaw, JB; Smith, RD; Ibrahim, YM
G Nagy, IK Attah, CR Conant, W Liu, SV Garimella
Anal. Chem 92 (7), 5004-5012, 2020
112020
Substance P in the gas phase: conformational changes and dissociations induced by collisional activation in a drift tube
CR Conant, DR Fuller, Z Zhang, DW Woodall, DH Russell, DE Clemmer
Journal of The American Society for Mass Spectrometry 30 (6), 932-945, 2019
112019
Evaluation of waveform profiles for traveling wave ion mobility separations in structures for lossless ion manipulations
CR Conant, IK Attah, SVB Garimella, G Nagy, A Bilbao, RD Smith, ...
Journal of the American Society for Mass Spectrometry 32 (1), 225-236, 2020
62020
Monitoring the stabilities of a mixture of peptides by mass-spectrometry-based techniques
DR Fuller, CR Conant, TJ El-Baba, Z Zhang, KR Molloy, CS Zhang, ...
European Journal of Mass Spectrometry 25 (1), 73-81, 2019
32019
Implementation of ion mobility spectrometry-based separations in structures for lossless ion manipulations (SLIM)
AL Hollerbach, CR Conant, G Nagy, YM Ibrahim
Biomedical Engineering Technologies: Volume 2, 453-469, 2022
22022
Diketopiperazine Formation from FPGnK (n = 1–9) Peptides: Rates of Structural Rearrangements and Mechanisms
Z Zhang, CR Conant, TJ El-Baba, SA Raab, DR Fuller, DA Hales, ...
The Journal of Physical Chemistry B 125 (29), 8107-8116, 2021
22021
Ion mobility spectrometer and method of operating same
DE Clemmer, MA Ewing, SM Zucker, CRP Conant
US Patent 9,368,333, 2016
22016
Ion mobility spectrometer and method of operating same
DE Clemmer, MA Ewing, SM Zucker, CRP Conant
US Patent 9,129,782, 2015
22015
The system can't perform the operation now. Try again later.
Articles 1–20