Conductivity and current density image reconstruction using harmonic Bz algorithm in magnetic resonance electrical impedance tomography SH Oh, BI Lee, EJ Woo, SY Lee, MH Cho, O Kwon, JK Seo Physics in Medicine & Biology 48 (19), 3101, 2003 | 252 | 2003 |
J-substitution algorithm in magnetic resonance electrical impedance tomography (MREIT): phantom experiments for static resistivity images HS Khang, BI Lee, SH Oh, EJ Woo, SY Lee, MH Cho, O Kwon, JR Yoon, ... IEEE transactions on medical imaging 21 (6), 695-702, 2002 | 157 | 2002 |
Electrical conductivity images of biological tissue phantoms in MREIT SH Oh, BI Lee, EJ Woo, SY Lee, TS Kim, O Kwon, JK Seo Physiological Measurement 26 (2), S279, 2005 | 119 | 2005 |
Noise analysis in magnetic resonance electrical impedance tomography at 3 and 11 T field strengths R Sadleir, S Grant, SU Zhang, BI Lee, HC Pyo, SH Oh, C Park, EJ Woo, ... Physiological measurement 26 (5), 875, 2005 | 116 | 2005 |
Experimental and numerical assessment of MRI‐induced temperature change and SAR distributions in phantoms and in vivo S Oh, AG Webb, T Neuberger, BS Park, CM Collins Magnetic Resonance in Medicine: An Official Journal of the International …, 2010 | 106 | 2010 |
Measurement of SAR‐induced temperature increase in a phantom and in vivo with comparison to numerical simulation S Oh, YC Ryu, G Carluccio, CT Sica, CM Collins Magnetic resonance in medicine 71 (5), 1923-1931, 2014 | 99 | 2014 |
Three-dimensional forward solver and its performance analysis for magnetic resonance electrical impedance tomography (MREIT) using recessed electrodes BI Lee, SH Oh, EJ Woo, SY Lee, MH Cho, O Kwon, JK Seo, JY Lee, ... Physics in Medicine & Biology 48 (13), 1971, 2003 | 94 | 2003 |
Magnetic resonance electrical impedance tomography at 3 Tesla field strength SH Oh, BI Lee, TS Park, SY Lee, EJ Woo, MH Cho, JK Seo, O Kwon Magnetic Resonance in Medicine: An Official Journal of the International …, 2004 | 80 | 2004 |
Bloch‐based MRI system simulator considering realistic electromagnetic fields for calculation of signal, noise, and specific absorption rate Z Cao, S Oh, CT Sica, JM McGarrity, T Horan, W Luo, CM Collins Magnetic resonance in medicine 72 (1), 237-247, 2014 | 58 | 2014 |
Permittivity and performance of dielectric pads with sintered ceramic beads in MRI: early experiments and simulations at 3 T W Luo, MT Lanagan, CT Sica, YC Ryu, S Oh, M Ketterman, QX Yang, ... Magnetic resonance in medicine 70 (1), 269-275, 2013 | 58 | 2013 |
An approach to rapid calculation of temperature change in tissue using spatial filters to approximate effects of thermal conduction G Carluccio, D Erricolo, S Oh, CM Collins IEEE Transactions on Biomedical Engineering 60 (6), 1735-1741, 2013 | 52 | 2013 |
Static resistivity image of a cubic saline phantom in magnetic resonance electrical impedance tomography (MREIT) BI Lee, SH Oh, EJ Woo, SY Lee, MH Cho, O Kwon, JK Seo, WS Baek Physiological measurement 24 (2), 579, 2003 | 51 | 2003 |
High field MREIT: setup and tissue phantom imaging at 11 T R Sadleir, S Grant, SU Zhang, SH Oh, BI Lee, EJ Woo Physiological measurement 27 (5), S261, 2006 | 32 | 2006 |
Electrical conductivity imaging by magnetic resonance electrical impedance tomography (MREIT) SH Oh, JY Han, SY Lee, MH Cho, BI Lee, EJ Woo Magnetic Resonance in Medicine: An Official Journal of the International …, 2003 | 31 | 2003 |
Complex difference constrained compressed sensing reconstruction for accelerated PRF thermometry with application to MRI‐induced RF heating Z Cao, S Oh, R Otazo, CT Sica, MA Griswold, CM Collins Magnetic Resonance in Medicine 73 (4), 1420-1431, 2015 | 29 | 2015 |
Improved homogeneity of the transmit field by simultaneous transmission with phased array and volume coil NI Avdievich, S Oh, HP Hetherington, CM Collins Journal of Magnetic Resonance Imaging 32 (2), 476-481, 2010 | 26 | 2010 |
Improved current source design to measure induced magnetic flux density distributions in MREIT O Tong-In, C Young, O Suk-Hoon, W Eung-Je Journal of Biomedical Engineering Research 27 (1), 30-37, 2006 | 24 | 2006 |
ISMRM best practices for safety testing of experimental RF hardware N De Zanche, C van den Berg, D Brunner, J Murphy-Boesch, J Rispoli, ... | 16 | 2022 |
Basic setup for breast conductivity imaging using magnetic resonance electrical impedance tomography BI Lee, SH Oh, TS Kim, EJ Woo, SY Lee, O Kwon, JK Seo Physics in Medicine & Biology 51 (2), 443, 2006 | 14 | 2006 |
A single current density component imaging by MRCDI without subject rotations SH Oh, IK Chun, SY Lee, MH Cho, CW Mun Magnetic resonance imaging 21 (9), 1023-1028, 2003 | 14 | 2003 |