Follow
Martin Brandt
Martin Brandt
Unknown affiliation
Verified email at surf.nl
Title
Cited by
Cited by
Year
Comparing image perception of bladder tumors in four different Storz professional image enhancement system modalities using the íSPIES app
GM Kamphuis, DM de Bruin, MJ Brandt, T Knoll, P Conort, A Lapini, ...
Journal of endourology 30 (5), 602-608, 2016
582016
Prostate cancer diagnosis: the feasibility of needle-based optical coherence tomography
BG Muller, DM de Bruin, W Van den Bos, MJ Brandt, JF Velu, MTJ Bus, ...
Journal of Medical Imaging 2 (3), 037501-037501, 2015
382015
Perfusion territories subtended by penetrating coronary arteries increase in size and decrease in number toward the subendocardium
P van Horssen, JPHM van den Wijngaard, MJ Brandt, IE Hoefer, ...
American Journal of Physiology-Heart and Circulatory Physiology 306 (4 …, 2014
362014
Prostate cancer diagnosis by optical coherence tomography: First results from a needle based optical platform for tissue sampling
BG Muller, DM de Bruin, MJ Brandt, W van den Bos, S van Huystee, ...
Journal of biophotonics 9 (5), 490-498, 2016
352016
Comparison of optical coherence tomography and histopathology in quantitative assessment of goat talus articular cartilage
P Cernohorsky, AC Kok, DM Bruin, MJ Brandt, DJ Faber, GJ Tuijthof, ...
Acta orthopaedica 86 (2), 257-263, 2015
332015
Needle-based optical coherence tomography for the detection of prostate cancer: a visual and quantitative analysis in 20 patients
BG Muller, RAA van Kollenburg, A Swaan, ECH Zwartkruis, MJ Brandt, ...
Journal of Biomedical Optics 23 (8), 086001-086001, 2018
252018
JJMCH de la Rosette, DM de Bruin, and TG van Leeuwen,“Needle-based optical coherence tomography for the detection of prostate cancer: a visual and quantitative analysis in 20 …
BG Muller, RAA van Kollenburg, A Swaan, ECH Zwartkruis, MJ Brandt, ...
J. Biomed. Opt 23 (08), 1, 2018
62018
Ex-vivo study in nephroureterectomy specimens defining the role of 3-D upper urinary tract visualization using optical coherence tomography and endoluminal …
MTJ Bus, P Cernohorsky, DM de Bruin, SL Meijer, GJ Streekstra, ...
Journal of Medical Imaging 5 (1), 017001-017001, 2018
42018
íSPIES: Comparing Image Perception of Bladder Tumors in Four Different Storz Professional Image Enhancement System Modalities Using the íSPIES App
GM Kamphuis, DM de Bruin, MJ Brandt, T Knoll, P Conort, A Lapini, ...
Journal of Endourology, Videourology 30 (3), 2016
2016
1052 From Gleason score to changes in scattering: Optical coherence tomography in prostate cancer–a prospective human ex-vivo study
BG Muller, W Van Den Bos, DM De Bruin, MJ Brandt, DJ Faber, ...
European Urology Supplements 1 (13), e1052, 2014
2014
11 Van lichtverstrooiing tot Gleason-score: ex-vivo optische coherentietomografie (OCT) van de menselijke prostaat na radicale prostatectomie
BG Muller, W van den Bos, DM de Bruin, MJ Brandt, DJ Faber, ...
Tijdschrift voor Urologie 3, 172-173, 2013
2013
Border zone coronary collateral network detected with an imaging cryomicrotome in the infarcted human heart
PHM Van den Wijngaard, P Van Horssen, AC Van der Wal, M Van Lier, ...
EUROPEAN HEART JOURNAL 33, 756-756, 2012
2012
Characterization of intramural branch segments in relation to myocardial depth
P van Horssen, J van den Wijngaard, MJ Brandt, IHJAE Spaan, M Siebes
Multiscale analysis of coronary branching and collateral connectivity …, 0
The system can't perform the operation now. Try again later.
Articles 1–13